Sign In | Join Free | My hardware-wholesale.com |
|
Brand Name : Uchi
Model Number : Power lightning protection box
Certification : CE / ISO9001 / FCC / SGS
Place of Origin : Dongguan China
MOQ : 50 piece / pieces
Price : Negotiate
Payment Terms : T/T, L/C
Supply Ability : 10000 pieces per month
Delivery Time : 8 - 15 days after payment
Packaging Details : Export package
Name : Lightning Protection Box
Shell material : Hard plastic
Protection mode selection : No N-G protection mode
Product Warranty : 1 Year
Application : Power Entrances
Protection class : NEMA 4X
Operating temperature range : -40℃…+80℃
The distinctive feature of this product is the output residual Low pressure and fast response time, especially when lightning surge passes through the protector, subsequent current will not appear. When the lightning protection box fails due to overheating, overcurrent, or breakdown due to lightning strikes, the built-in failure trip device can automatically disconnect it from the grid.
Product Description:
Adopting Class II SPD to combine “3+1” circuit, protecting low voltage equipment from surge damages, applied in TT system, designed according to IEC61643-1/GB 18802.1
Main character:
1. Green light indicates normal and red light indicates fault for operation
2. Built-in circuit breaker, and thermal disconnection device, when the fault occurred, the thermal disconnection device will cut off the SPD from the power net, the green window will change
3. Impulse counter function, recording the lightning events
4. External wiring terminal, easy for connection, suitable for indoor application
Type | BT 5L CM 275/40 4P | BT 5L CM 385/40 4P | BT 5L CM 275/40 3+1 | BT 5L CM 385/40 3+1 | |
Order No. | 840 883 | 840 887 | 840 884 | 840 888 | |
Norminal a.c. voltage | UN | 230V/400V | 230V/400V | 230V/400V | 230V/400V |
Rated voltage (max. continuous a.c voltage) L/N | Uc | 275V | 385V | 275V | 385V |
Rated voltage (max. continuous a.c voltage) N/PE | Uc | 275V | 385V | 255V | 255V |
Nominal discharge current (8/20µs) L/N | In | 20KA | 20KA | 20KA | 20KA |
Nominal discharge current (8/20µs) N/PE | In | 20KA | 20KA | 40KA | 40KA |
Max. discharge current (8/20µs) L/N | Imax | 40KA | 40KA | 40KA | 40KA |
Max. discharge current (8/20µs) N/PE | Imax | 40KA | 40KA | 65KA | 65KA |
Voltage protection level L/N | Up | ≤1.25KV | ≤1.8KV | ≤1.25KV | ≤1.8KV |
Voltage protection level N/PE | Up | ≤1.25KV | ≤1.8KV | ≤1.5KV | ≤1.5KV |
Follow current extinguishing capability at Uc (N/E) | IL | 100Arms | 100Arms | ||
Operating temperature range | -40℃…+80℃ | ||||
Cross-sectional area | 25mm2 solid/35mm2 flexible | ||||
Enclosure material | black metal housing (die-casting Aluminum) | ||||
Test standards | YD/T 1235.1; GB 18802.1; IEC 61643-1 | ||||
Certification | CE (LVD, EMC) |
![]() |